CAT6a Patch and Bulk Cables
CAT6a Patch Panels
CAT6a Keystones
Belkin's CAT6a channel and permanent link configurations are ETL-verified to pass
all TIA/ETL-568-B.2-10 requirements .
Request More Information
|
|
|
Thank you for your interest in Belkin's CAT6a Datacenter Solutions. Please complete the form below
to request more information regarding CAT6a solutions.
|
Features and Benefits:
- Compliant to Industry Standards - Official TIA/EIA568-B.2-10 and ISO/IEC 11801-compliant
- Meets all Alien crosstalk reduction specifications - not affected by wire in adjacent
cable
- 10Gbit/s transmission to 100m
- Performance Tested - Tested to exceed 500MHz
- CAT6a Copper Patch Cables feature Molded Connectors with Snagless Guards - Make
installations effortless and protect connector tabs from damage
- CAT6a Copper Patch Cables feature Gold-Plated Connector Contacts - Deliver maximum
conductivity for high-speed data transmissions
- Backward compatible with CAT5e and CAT6
Third-Party Independent Testing
Belkin's CAT6a end-to-end solution passes all TIA/ETL-568-B.2-10 requirements in
both "channel" and "permanent link" configurations, including alien cross talk,
return loss, insertion loss, propagation delay, and delay skew.
Channel Configuration:
Belkin CAT6a Patch Cables (F2CP003)
Belkin Patch Panels (F4P600)
Belkin Keystone (F2CP006-H)
Belkin Bulk Cable (F2CP004-1000)
Permanent Link Configuration:
In the "Permanent Link" configuration, testing is conducted on Belkin bulk cable
terminated with Belkin keystones:
Belkin Bulk Cable (F2CP004-1000)
Belkin Keystones (F2CP006-H)
Product Line
Belkin CAT6a end-to-end solutions are ETL-verified to pass all TIA/ETL-568-B.2-10
requirements, including alien crosstalk, return loss, insertion loss, propagation
delay, and delay skew, in both channel and permanent link configurations.
- Keystones and Patch panels
- Patch cords in various lengths: 1', 3', 5', 7', 10', 14', 20', & 25'
- Bulk: 1000' pull box, Stranded CM (standard) and Solid CMR (riser)
- Cable Colors: Aqua, Black, and Gray
FAQ
What is the difference between the "draft" and "official" versions of TIA/EIA-568-B.2-10?
"Draft" versions: proposed specifications published as guidelines to the cable
and equipment manufacturers. "Official" version: actual specifications that manufacturers
will be held accountable to.
What is "ETL"? ETL (Edison Testing Labs) is a subsidiary of a 3rd-party testing
house called Intertek. ETL tests the cable according to the TIA/EIA specification
and supplies verification of the cables' conformance to the spec.
What is "ETL-Verified" Cable? ETL has tested and certifies that the cable
passes all requirements in the official TIA/EIA specification.
Is Belkin's bulk cable "ETL-Verified"? Our bulk cable is "ETL-Verified" to
the official CAT6a spec in the "Permanent Link" and "Channel" configurations.
Is Belkin's patch cord "ETL-Verified"? Our patch cords are "ETL-Verified"
to the official CAT6a spec in the "Channel" configuration only.
What is Permanent Link configuration? Keystone + Bulk cable + Keystone. Keystones
can be in a patch panel or a wall plate.
What is Channel configuration? Patch cord + Keystone + Bulk cable + Patch
panel + Patch cord + Patch panel + Patch cord.